LCZ-35Q 35kV Manual Switch CT Current Transformer Indoor Insulated Structure

Xi'an Xigao Electricenergy Group Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

LCZ-35Q 35kV Manual Switch CT Current Transformer Indoor Insulated Structure

Brand Name : XG

Model Number : LCZ35Q

Certification : ISO

Place of Origin : XIAN,CHINA

MOQ : 2-3 SET

Payment Terms : L/C, D/P, T/T, D/A, D/A, D/P, Western Union, MoneyGram

Supply Ability : 2000 SET

Delivery Time : 3-7 DAYS

Packaging Details : WOODEN CASE

ratd voltage : 6KV 10kv 11KV

Ambient temperature : -45℃ - +40℃

Rated Voltage : 35kV

phase : single

Accuracy class : 0.5, 0.2S, 10P, 5P20

rated insulation level : 12/42/75kV

Rated Secondary Voltage : 35

Type : Full-Enclosed Post-Type

Rated Second Current : 5A(2A,1A)

Contact Now

1.LCZ-35Q 35kV Indoor Old Semi-Closed Insulation Structure Manual Type Switchgear Current Transformer


LCZ-35Q current transformer is semi-closed insulated cast product, suitable for power metering, current measurement and relay protection in power system with rated frequency of 50Hz or 60Hz and rated voltage of 35kV and below.
This product conforms to IEC44-1 and GB1208 "current transformer".


2.The structure of


This TYPE OF current intercurrent device is semi-closed pillar structure, the primary winding is poured in epoxy resin, and the secondary winding and iron core are installed outside.
LCZ-35Q current transformer has strengthened external insulation and is a working condition product.
LCZ-35G is suitable for switchgear with width of 1.2 m.


3.The principle of use


1) The connection of the CT shall comply with the series principle: that is, the primary winding resistance shall be connected in series with the circuit under test, and the secondary winding resistance shall be connected in series with all instrument loads
2) Select appropriate changes according to the measured current, otherwise the error will increase. At the same time, one end of the secondary side must be grounded to prevent the high pressure of the primary side from running into the secondary low pressure side once the insulation is damaged, which may cause personal and equipment accidents
3) The open circuit of the secondary side is absolutely not allowed, because once the open circuit is opened, the current I1 of the primary side will all become the magnetizing current, causing a sharp increase in φm and E2, resulting in oversaturated magnetization of the core, serious heating and even burning the coil; At the same time, over-saturating magnetization of the magnetic circuit increases the error. Current transformer in normal work, the secondary side is akin to short circuit, if all of a sudden make its open circuit, the excitation electromotive force by the numerical small change value of great value in the core flux present serious saturation flat wave, therefore the secondary winding through zero in magnetic induction out high steeple wave, its value can reach thousands or even tens of thousands of volts, Endanger the safety of the staff and the insulation performance of the instrument. In addition, the open circuit of the secondary side makes the voltage of the secondary side reach hundreds of volts, once touched, it will cause electric shock accident. Therefore, the secondary side of the current transformer is equipped with a short circuit switch to prevent the open of the secondary side. In the process of use, once the secondary side open circuit should immediately remove the circuit load, and then, and then power off treatment. Take care of everything before you use it again.

4.TECHNICAL PARAMETER

Ratde Primary Current(A) Accuracy Classes(1S/2S) Rated Secondary Output (VA) 4S Thermo Stability Current(kA Virtual Value) Dynamic Stability Current(kA Peak)
0.2S,0.2 0.5S,0.5 10P10 10P15
15 0.2S/10P 0.5S/10P 0.2/10 0.5/10P 0.2/0.5 20 40 30 20 3.15 7.8
20 4.5 11
30 6.3 15
40 9 22.5
50 12.5 3.5
75 16 37.5
100 25 62.5
150 31.5 78
200
300 30 50 60 50
400 50
500
600
800 45 100
1000 55
1200 63 130
1500 72
2000 80

5.TECHNICAL DRAWING

LCZ-35Q 35kV Manual Switch CT Current Transformer Indoor Insulated Structure

6.FAQ:

1. Send the technical data, better for all useful information; we will make a good recommendation.

possible please attach one reference picture to avoid any misunderstanding or any links from our website for we get a better understanding.

2. The lead time depend on quantity of order. Some standard type is on stock. Otherwise, it will take 3-15 days.

3. Usually shipped by sea, small order or urgent order we can send you by air.

4. All our activities are accredited to ISO 14001:2015 and IEC standard.

5. Technology ensure the quality satisfy international request.


Product Tags:

Manual Switch CT Current Transformer

      

Indoor Insulated CT Current Transformer

      

35kV Current Transformer

      
Best LCZ-35Q 35kV Manual Switch CT Current Transformer Indoor Insulated Structure wholesale

LCZ-35Q 35kV Manual Switch CT Current Transformer Indoor Insulated Structure Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Xigao Electricenergy Group Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)